- Upon request, Uni-Jet 75, Tecno-Jet and Flux-Jet aspiration units can be supplied with their boxes.
- Electrical control panels are manufactured according to IEC EN 61439-1 (2009-11) regulations; they
are fitted with low tension control cables. - The connecting device for the electronic circuit of all electronic control panels (i.e. all control panels
marked by a final E, like C75/1E, C75/E etc.) must be completed with a peripheral P.B. unit to be
placed next to the work station. - Control panels designed for two or more aspiration units are fitted with an electronic device to
start/stop automatically one or more motors according to aspiration demand. - Each suction machine can service a variable number of work stations depending on different
parameters: diameter and length of the piping, brand of the bench, number of bends
(requirements concerning aspiration can vary), therefore the number of work stations we suggest
should not be considered as binding.
- Sound pressure level tested according to ISO regulation 3746 -1979 (E).
Parameters: r =1.5 – background noise < 38 dB (A) – Instrument: Brüel & Kjær type 2232.
The motor is protected by a thermal
device. Output power single-phase 0.37
kW – 2.9 A, maximum flow 1250 l/min,
maximum operating head for continuous
service 1300 mm H2O. Suggested for
single work station.
Sound pressure level with canalized
air 62 dB (A). W= 231.5 mm D= 246 mm
H= 251 mm Net Weight= 10 kg (Gross
Weight= 11 kg)
Output power single-phase 0.75 kW – 5.5 A,
maximum flow 2000 l/min,
maximum operating head for continuous
service 1300 mm H2O.
Suggested for one work station at 8-10 m
distance.
Sound pressure level with canalized air
68 dB (A).
W= 302.5 mm D= 302 mm H= 319 mm
Net Weight= 18 kg (Gross Weight= 20 kg)
Output power three-phase 0.75 kW
– 4.2/2.4 A, maximum flow 2000 l/min,
maximum operating head for continuous
service 1300 mm H2O.
Suggested for one work station at 8-10 m
distance.
Sound pressure level with canalized air
68 dB (A).
W= 302.5 mm D= 302 mm H= 319 mm
Net Weight= 18 kg (Gross Weight= 20 kg)
For two Tecno-Jet single-phase.
W= 400 mm D= 220 mm H= 580 mm
For two Tecno-Jet three-phase .
W= 400 mm D= 220 mm H= 580 mm
Output power three-phase 1.5 kW
– 6,9/4 A, maximum flow 3300 l/min,
maximum operating head for continuous
service 1500 mm H2O.
Suggested for 2 work stations at 8-10
m distance. Sound pressure level with
canalized air 68.5 dB (A). W= 334 mm
D=294 mm H= 341 mm.
Net Weight= 22 kg (Gross Weight= 24 kg)
Output power single-phase 1.1 kW – 7.6
A, maximum flow 3300 l/min,
maximum operating head for continuous
service 1500 mm H2O.
Suggested for 2 work stations at 8-10
m distance. Sound pressure level with
canalized air 68.5 dB (A). W= 334 mm D=
294 mm H= 341 mm.
Net Weight= 22 kg (Gross Weight= 24 kg)
For two Flux-Jet three-phase.
W= 400 mm D= 220 mm H= 580 mm.
For two Flux-Jet single-phase.
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 2.2 kW – 9/5.2
A, maximum flow 5000 l/min, maximum
operating head for continuous service
1750 mm H2O. Suggested for 3 work
stations working at the same time at 10-
12 m distance. Sound pressure level with
canalized air 76 dB (A).
W= 395 mm D= 332 mm H= 415 mm.
Net Weight= 30 kg (Gross Weight= 35 kg)
For two Medio-Jet three-phase.
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 4 kW –
16.7/9.7 A, maximum flow 8333 l/min,
maximum operating head for continuous
service 1700 mm H2O. Suggested for 4
work stations working at the same time
at 10-15 m distance. Sound pressure
level with canalized air 76.5 dB (A). W=
566 mm D= 422 mm H= 443 mm.
Net Weight= 54 kg (Gross Weight= 60 kg)
For 2 Maxi-Jet 2S three-phase
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 3.5 kW –
14.7/8.5 A, maximum flow 9500 l/min,
maximum operating head for continuous
service 1300 mm H2O. Suggested for 6
work stations working at the same time
at 20 m distance. Sound pressure level
with canalized air 78 dB (A). W= 530 mm
D= 530 mm H= 585 mm. Net Weight= 90
kg (Gross Weight= 105 kg)
For 2 Uni-Jet 500 three-phase
W= 400 mm D= 220 mm H= 580 mm.
Output power three-phase 4.5 kW –
18.2/10.5 A, maximum flow 20000 l/min,
maximum operating head for continuous
service 1200 mm H2O. Suggested for 12
work stations working at the same time
at 25 m distance. Sound pressure level
with canalized air 82 dB (A).
W= 570 mm D= 645 mm H= 625 mm.
Net Weight= 118 kg (Gross Weight= 133 kg)
For two Uni-Jets 1000 three-phase.
W= 300 mm D= 170 mm H= 400 mm.
The peripheral P.B. unit is required only
with electronic control panels (those
marked by a final E, like C75/1E, C75/E).
One for each work station.
W= 70 mm D= 70 mm H= 22 mm.
The filter cleaning is carried out
automatically by compressed air.
Dust collects inside a disposable plastic
bag which can be easily taken out.
Max. air flow 700 m3/h – up to 7 work
stations in aspiration.
W= 505 mm D= 590 mm H= 1275 mm.
Net Weight= 70 kg (Gross Weight= 80 kg)
DIN EN 60335-2-69 filters.
The filter cleaning is carried out
automatically by compressed air. Dust
collects inside a disposable plastic bag
which can be easily taken out. Max.
air flow 1500 m3/h – 14 work stations in
aspiration.
W= 650 mm D= 700 mm H= 1950 mm Net
Weight= 84 kg (Gross Weight= 100 kg)
The filter cleaning is carried out
automatically by compressed air. Dust
collects inside a disposable plastic bag
which can be easily taken out. Max.
air flow 1100 m3/h – 12 work stations in
aspiration.
W= 650 mm D= 700 mm H= 1950 mm Net
Weight= 84 kg (Gross Weight= 100 kg)
The filter cleaning is carried out
automatically by compressed air. Dust
collects inside a disposable plastic bag
which can be easily taken out. Max.
air flow 900 m3/h – 9 work stations in
aspiration.
W= 650 mm D= 700 mm H= 1950 mm Net
Weight= 84 kg (Gross Weight= 100 kg)
DIN EN 60335-2-69 filters.